Overview

This guide explains how to configure Lockers on the Integriti system. Locker Banks allow you to manage electronic locker access using card readers, with real-time allocation status displayed in the software.

There are three Allocation Modes for Locker Banks:

ModeNormallyReader TypeAllocationLive Status
Dynamic – UnlimitedUnlockedReader per LockerUnlimited per bankYes
Dynamic – 1 Per User (per bank)UnlockedReader per Locker1 locker per user per bankYes
Pre-AssignedLockedReader per Bank or per LockerPer-user assignment onlyNo

Limits: 1000 Lockers per Controller, 10 Locker Banks per Controller. Licensing: Locker Count Licence (Part #996235) — 1 licence = 10 Lockers.

Prerequisites

  • Integriti Pro Software Version 16 or later.
  • ISC/IAC Controller Firmware Version 16 or later.
  • Integriti/Concept Door Controllers (ILAM or SLAM modules).
  • SIFER readers (or compatible readers) assigned to each locker or bank.
  • UniBus 8-Relay Auxiliary Expanders (one auxiliary per locker).
  • Smart Card Locker Licence (Part #996235).

Step-by-Step

Dynamic – Unlimited Mode (10 Lockers, Individual Readers)

  1. Configure the ILAM readers for SIFER and assign the correct serial numbers. Leave the Reader Purpose as Control Door — this will be changed later.
  2. Navigate to Access Control → Locker Banks.
  3. Click Add New and name the Locker Bank.
  4. Leave the Allocation Mode as Dynamic – Unlimited.
  5. Click Save, then click Bulk Create Lockers.
  6. Select the Start Auxiliary (e.g. C01:X01).
  7. Set How Many to the number of lockers (e.g. 10).
  8. Select the ILAM module from the drop-down.
  9. Enable Re-purpose existing reader’s option.
  10. Click Create Lockers.
  11. Verify that the first 10 readers on the ILAM now have a purpose of Access Locker / Locker Bank and each reader has a unique Locker assigned.
  12. Assign the Locker Bank to the Users’ Permission structure.

Dynamic – 1 Per User Mode (20 Lockers Across 2 Floors)

  1. Configure both ILAM readers for SIFER and assign correct serial numbers.
  2. Navigate to Access Control → Locker Banks and click Add New.
  3. Name the bank (e.g. “Ground Floor Lockers”).
  4. Change the Allocation Mode to Dynamic – 1 Per User (per bank).
  5. Click Save, then Bulk Create Lockers.
  6. Set Start Auxiliary to C01:X01, How Many to 10.
  7. Select the ground floor ILAM and enable Re-purpose existing reader’s.
  8. Click Create Lockers.
  9. Assign the Locker Bank to the Users’ Permission structure.
  10. Repeat steps 2–9 for the second floor, creating a new Locker Bank (e.g. “First Floor Lockers”) starting at C01:X11.

Pre-Assigned Mode (10 Lockers, Central Reader)

  1. Configure the SLAM reader for SIFER and assign the correct serial number. Leave Reader Purpose as Control Door.
  2. Navigate to Access Control → Locker Banks and click Add New.
  3. Change the Allocation Mode to Pre-Assigned.
  4. Set the Unlock Time (e.g. 30 seconds; a value of 0 defaults to 5 seconds).
  5. Click Save, then Bulk Create Lockers.
  6. Set Start Auxiliary (e.g. C01:X01) and How Many to 10.
  7. De-select Assign a reader to each Locker.
  8. Click Create Lockers.
  9. Edit the SLAM’s Reader 1: change Reader Purpose to Access Locker / Locker Bank and assign the Pre-Assigned Locker Bank to the reader.
  10. Assign individual Lockers to Users’ Permission structure (Locker Banks cannot be assigned per-user in this mode).

Verification

  1. Present a valid user credential at a locker reader.
  2. Verify the locker unlocks (Dynamic modes) or unlocks timed (Pre-Assigned).
  3. In the Integriti software, check that the locker shows as assigned to the user (Dynamic modes only — Pre-Assigned does not show live status).
  4. Check Integriti Review for access granted/denied messages.
  5. Test Locker Override: use an Override Card (enabled under Menu Group → Access Control Settings) to unlock a dynamically allocated locker.

Troubleshooting

SymptomResolution
Locker does not unlockVerify the auxiliary is correctly mapped and the UniBus 8-Relay expander is online.
User denied at locker (already allocated)User already has a locker in that bank (Dynamic 1 Per User). Use Locker Override to de-allocate.
No live status shownPre-Assigned mode does not support live allocation status. Switch to a Dynamic mode.
Power failure loses allocationsDynamic mode allocations reset on controller power loss (lockers remain locked but status is lost).
SIFER LED not reflecting locker stateEnable the Reader Feedback option on the SIFER reader — red = locked, green = unlocked.

Locker Control Commands

Right-click a Locker in the software for these commands:

CommandOutcome
Toggle StateToggles the locker state and de-allocates the associated user.
UnlockUnlocks the locker and de-allocates the associated user.
Lock & DisableIf available, the locker will be locked and disabled.
Assign to UserIf available, locks and assigns to a user with the bank in their permissions.

Right-click a Locker Bank for Name Auxiliaries (names auxiliaries according to locker names) or Locker Wizard (re-launches the wizard).